The most common accessory (usually a diamond or zinc selenide crystal) used for analyzing solids, powders, gels, and liquids directly without sample preparation.
Navigate directly to the official PerkinElmer / Revvity website. Under the "Support" or "Resources" section, look for the Product Documentation portal. Enter "Spectrum Two" to access official PDFs for user guides, installation manuals, and safety notes free of charge.
: USB 2.0 or Ethernet point-to-point connections.
The Spectrum Two is controlled via PerkinElmer’s Spectrum 10 (or Spectrum ES for regulated environments) software suite. Running Ready-to-Measure (RTM) Verifications
For specialized analyses, the system offers configurable options including sample preparation, instrument setup, data collection, and data analysis. The system supports various sampling modes including: spectrum two ftir spectrometer manual free
The UATR (Universal Attenuated Total Reflectance) accessory has its own dedicated user manual that outlines the procedure for obtaining a sample spectrum when your Spectrum Two is fitted with a UATR. The UATR user manual is available at: manualslib.com/manual/1764297/Perkinelmer-Spectrum-Two-Hatr.html
Keeps internal cavity dry. Packs can be regenerated in a lab oven at specified manual temperatures. Every 3–5 Years (or upon failure)
Before testing a sample, scan a background to account for atmospheric water vapor and CO2cap C cap O sub 2 . Ensure the crystal or sample holder is clean and empty. Sample Preparation:
The PerkinElmer Spectrum Two is a highly reliable, compact Fourier-Transform Infrared (FTIR) spectrometer used widely in academic, pharmaceutical, polymer, and environmental laboratories. Whether you are a student setting up your first experiment, a lab manager troubleshooting an error, or a researcher validating a protocol, having immediate access to the instruction manual is critical for maintaining data integrity and instrument health. The most common accessory (usually a diamond or
The manual heavily emphasizes the modularity of the Spectrum Two. It utilizes a kinematically mounted sample compartment, allowing users to swap accessories instantly without manual realignment. The software automatically recognizes the attached accessory, which may include:
Collect a fresh background spectrum immediately before running your next sample. Enable atmospheric compensation settings within the Spectrum software setup options to mathematically suppress residual contributions.
When the instrument encounters an issue, the onboard status LEDs or the software will flag specific faults. Referencing the manual’s troubleshooting matrix allows quick fixes for common problems: Issue 1: "Low Energy Detected" or "No Signal"
: Ensure you have read the appropriate Material Safety Data Sheets (MSDS) available from PerkinElmer's website. Enter "Spectrum Two" to access official PDFs for
Ensure the sampling area is clean and empty. If using a UATR accessory, ensure the pressure arm is swung away from the crystal.
Wait for the software to run its automatic diagnostics. A green checkmark indicates the instrument is aligned, calibrated, and ready for use. Step 2: Selecting and Installing Accessories
: The spectrometer can operate in ratio, single-beam, or interferogram mode.
If your lab performs repetitive testing (e.g., verifying the purity of incoming chemical lots), you can use the software’s . By uploading a verified standard spectrum to your local library, the software will automatically output a "Pass/Fail" metric based on a correlation coefficient (usually requiring >0.95 for a pass). This reduces human error and removes the need for manual spectrum interpretation by entry-level technicians.